8.10 TROUBLESHOOTING - ERROR 0149
CHAPTER 8: TROUBLESHOOTING
FIGURE A
ERROR CODE 0149
1) SYMPTOM:
0149 – The resistance current is over 3.7A for 1 second.
2) SOLUTION:
1) Check if the resistance is short circuited by measuring amperage through the power resistance cable (Figure A).
- If the resistance value is under 10 ohms, replace the power resistance.
- If the resistance value is over 10 ohms, replace the LCB.